MIL-PRF-23236D
3.2.2.3 Hazardous air pollutant (HAP) content of Types V, VI, VII, VIII, and VIIIa coatings. When evaluated
as specified in 4.5.6, the content of HAPs in each individual coating of Types V, VI, VII, VIII, and VIIIa shall be
less than the VOC limit prescribed for the specific types. Within this limitation and the requirement that the finished
coating meet all requirements of this specification, Types V, VI, and VII coating systems solvent selection is the
responsibility of the manufacturer.
3.2.3 Hazardous pigments and additives.
3.2.3.1 Types V, VI, VII, VIII, and VIIIa. When tested as specified in 4.5.10, the content of each soluble metal
and the total content of each metal of the coating shall be less than the values listed in tables I and II. In addition,
asbestos and asbestiform pigments shall be less than 0.5 percent by weight (wt%) of the dry paint film. Crystalline
silica shall not exceed 0.1 wt%. If the total metal content for an individual metal is less than the allowed soluble
metal content for that metal, the total metal value may be submitted for the soluble metal value and the actual test for
soluble metal need not be performed.
TABLE I. Soluble metals content for Type V, VI, VII, VIII, and VIIIa coatings.
Soluble metal and/or its compound in
Maximum, mg/L
each individual dry paint
Antimony
15
Arsenic
5
Barium (excluding barite)
100
Beryllium
0.75
Cadmium
1
Chromium (VI)
1
Chromium and/or chromium (III)
560
Cobalt
50
Copper
25
Fluoride salts
180
Lead
5
Mercury
0.2
Molybdenum
350
Nickel
20
Selenium
1
Silver
5
Tantalum
100
Thallium
7
Tungsten
100
Vanadium
24
Zinc
250