MIL-DTL-53072E
1/ 2/
TABLE II. General application guidelines for epoxy primers.
Specification
Mixing
Reduction
Application
Stir and strain. Set
Slowly add component B
MIL-PRF-23377
Spray with one full coat.
30 minutes before
to component A. Preferred
Wait 4-6 hours prior to
use, unless
topcoating. Use within 8
temperature range 60 to 90
induction time is
hours. Apply at a dry
o
F (16 to 32 șC) prior to
not required, per
film thickness (DFT) of
mixing as specified by the
manufacturer's
0.8-1.2 mils. 3/
manufacturer.
instructions.
Reduction does not
Follow the instructions
MIL-PRF-32348,
Follow the instructions
apply, since these
from the manufacturer for
from the manufacturer.
type I and II
products are
preparation and
powder coatings
application.
and do not use
solvents.
MIL-DTL-53022
One part component B to
If necessary and
Spray with one full coat.
four parts component A.
allowed, reduce
Wait 30-60 minutes prior
Add B to A. Preferred
types III and IV
to topcoating. Use within
temperature range 60 to 90 with a VOHAP-
4-6 hours for type II, III
o
F (16 to 32 șC) prior to
free thinner, as
and IV. DFT: 1.5 ± 0.2
mixing.
specified in 3.7.1,
mils.
or supplied by the
manufacturer, not
to exceed VOC
limits where
applicable. Type II
primer may also be
thinned with MIL-
T-81772, types I or
II. Stir and strain.
Set 30 minutes
before use or as
recommended by
manufacturer.
MIL-DTL-53030
Mix component A until
Using deionized
Spray with one full coat.
uniform. One part
water, reduce
Wait 30-60 minutes
component B with three
according to
before topcoating. Use
parts component A for
manufacturers'
within 6 hours. DFT: 1.5
type I and 1 part
instructions. Use
± 0.2 mils. High
component B to 4 parts
mechanical mixer
humidity retards dry, low
component A for type II.
and add water
humidity accelerates dry.
Add B to A. Preferred
slowly. Mix and
Make sure surface is free
temperature range 60 to 90
strain. Stir 30
of water prior to
oF (16 to 32 șC).
minutes before
topcoating.
use.
MIL-DTL-53084
Follow the manufacturers'
Reduce with very
Follow the instructions
instructions.
pure deionized
from the manufacturer.
water.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.