MIL-PRF-23236D
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a.
Qualification inspection (see 4.2).
b.
Conformance inspection (see 4.3).
4.2 Qualification inspection. Qualification inspection shall be as follows:
a. Qualification approval for Types VI and VII shall also constitute approval for Type V coating systems of
the same class and grade.
b. Qualification approval for Type VII shall also constitute approval for Types V and VI coatings of the same
class and grade.
c.
Qualification approval for Types VIII and VIIIa is unique and not extended to other types.
4.3 Conformance inspection. Conformance inspection shall consist of the conformance tests specified in
table V.
4.4 Panel preparation. Test plates of the nature and size specified in the applicable test method shall be coated
in accordance with the manufacturer's application instructions. Each individual coating of the coating system shall
be mixed in accordance with the manufacturer's mixing instructions.
4.5 Test procedures. Tests shall be conducted as specified in table V. The temperature at which tests are
conducted shall be in accordance with the applicable FED-STD-141 and ASTM test methods identified in table V.
For reduced temperature materials (Grades A and B), tests shall be conducted at the low end of the temperature
range. Unless otherwise specified herein, test panel dimensions and test conditions, such as temperature, are
nominal.
17