MIL-PRF-81352C
·
Specification MIL-PRF-81352C, "Coating, Aircraft Touch-up"
·
Type number and name (see 1.2.1)
·
Color (FED-STD-595 color name and number)
·
Manufacturer's name, product identification, and lot number
·
Date of manufacture (month/year)
·
VOC content (g/l) and type of thinner compatible with the coating
·
Net contents
·
Mixing instructions
4. VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are classified
as follows:
a. Qualification inspection (see 4.3)
b. Conformance inspection (see 4.4).
4.2 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with ASTM-D3924. Unless otherwise stated in the test method or paragraph, room
temperature shall be 70 ±10 °F (21 ±5 °C) and relative humidity of 50 ±10 percent.
4.3 Qualification inspection. The qualification inspection shall consist of all examinations
and tests specified in table II.
4.3.1 Qualification inspection samples. The test samples for qualification shall consist of
one quart of the FED-STD-595, colors 17925 and 36375. The material shall be furnished in the
type containers to be used in filling contract orders (see 6.3.1).
4.4 Conformance inspection. The conformance inspection shall consist of all the
examinations and tests specified in table II except composition, extended storage stability,
accelerated storage stability, and weather resistance. In the event that a test sample fails to meet
any requirement of this specification, the lot (see 6.5) represented by the sample shall be rejected.
4.4.1 Sampling.
4.4.2 Sampling for conformance tests. Samples shall be selected in accordance with
ASTM-D3925.
4.4.3 Sampling of filled containers. Samples shall be selected at random from each lot in
accordance with ASQ-Z1.4.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business