MIL-PRF-85285E
TABLE I. VOHAP limits.
Type
Class
Color/Finish
VOHAP
VOHAP
Limit (lb/gal)
Limit (g/l)
I
H
17925, Gloss/Semi-Gloss
0.20
24
I
H
36375, Camouflage
0.27
32
II
H
17925, Gloss/Semi-Gloss
1.33
159
II
H
36375, Camouflage
1.19
142
III
W
17925, Gloss
0.03
3
III
W
36375, Camouflage
N/A
N/A
IV
H
17925, Gloss/Semi-Gloss
1.30
156
IV
H
36375, Camouflage
0.80
95
3.5 Component properties.
3.5.1 Condition in container.
3.5.1.1 Component A. When tested in accordance with 4.6.1, component A shall be
smooth, homogeneous, and pourable. The coating shall be free of grit, skin, seeds, lumps,
foreign contaminants, and abnormal thickening or livering, and shall not exhibit pigment
floatation nor excessive settling that cannot be reincorporated into a smooth, homogeneous state
by mixing with a hand paddle.
3.5.1.2 Component B. Component B shall be homogeneous, clear, and free from gelation
or detectable particulate matter, either suspended in solution or settled on the inner surface of the
container. Component B shall not cause its container to deform (see 4.6.1).
3.5.1.3 Component C, Class H (if applicable). Component C shall be clear and contain
predominately organic solvents. Component C shall not cause its container to deform (see 4.6.1).
3.5.2 Storage stability. The unopened coating components, as packaged by the
manufacturer, shall meet all requirements of this specification after storage for a period of one
year for metal containers and six months for plastic containers (see 4.6 and 6.5.2). The
conditions for the storage shall be a daily ambient air temperature that is maintained at
1.7 to 46 oC (35 to 115 oF).
3.5.3 Accelerated storage stability. The coating components, after storage for 14 days (see
4.6.2) as packaged by the manufacturer, when admixed shall meet all requirements of this
specification. The containers shall not become deformed or the lid shall not become unsealed
during the storage period.
3.5.4 Freeze-thaw stability (class W only). The coating components, as packaged by the
manufacturer, shall meet all the requirements of this specification after being subjected to five
cycles of freezing and thawing as specified in 4.6.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business