TT-P-1757B
"CAUTION
AVOID BREATHING VAPOR
USE ONLY IN ADEQUATELY VENTILATED AREA"
5.2.3.1 Class C primer coating. In addition to the marking required in 5.2.3, the following shall appear on each container of class C primer coating: "CONTAINS CHROMATES."
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. This primer coating is intended for use as a corrosion inhibiting primer coating on aluminum and aluminum alloy structures and surfaces and on surfaces coated with a pretreatment coating conforming to MIL-C-8514 or DOD-P-15328. The recommended dry film thickness is 15.2 to 22.9 m (0.6 to 0.9 mil). Suggested testing for dip or flow-coat application is as follows:
Dip application: Dip a test panel, with approximate dimensions of 101.5 by 305 mm (4 by 12 in.), full-length, into the primer coating, whose viscosity has been reduced as specified by the manufacturer. Upon removal from the primer coating, examine the test panel. If the film is not uniform in appearance and free from color separation, runs, sags or streaks, it is unsuitable for dip application.
Flow-coat application. When applied by flow-coating to a glass panel, the primer coating should produce a continuous film, free from grit, seeds, streaks, blisters, or other surface irregularity.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number and date of this specification, including any amendments.
b. Issue of DoDISS to be cited in the solicitation and, if required, the specific issue of individual documents referenced (see 2.1 and 2.2).
c. Type, class, and color (see 1.2 through 1.2.3). d. If a test report is required (see 4.3.3).
e. Quantity, size, and type of containers (see 5.1.1 and 6.3). f. If reduced testing is permitted (see 6.2.1)
6.2.1 Reduced testing provisions. Purchasers have the option of permitting reduced testing requirements on material supplied to this specification when the manufacturer has historical test data that is less than five years old. Reduced testing is defined as all of the tests of this
17
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business