MIL-DTL-11195H
shall consist of a one quart paint sample. The sample and necessary paperwork (see 6.3.1) shall
be sent to the qualifying activity (see 6.3).
TABLE IV. Colors tested by full qualification testing or extension testing for qualification.
Primary Colors
Secondary Colors
30117
-
31136
31158
33538
33655
34079
-
34088
34082, 34108
34540
-
35044
35109, 35193
37038
-
33446, 34558, 36118, 36231, 36375, 36440,
37925
37142, 37875
4.4 Conformance inspection. The manufacturer shall forward from each production lot (see 4.4.1)
a batch validation letter detailing the batch number, manufacturer's code, specification and type
number, QPL number and batch volume to U.S. Army Research Laboratory (ARL), ATTN:
RDRL-WMM-C, Organic Coatings Team, Building 4600, Deer Creek Loop, Aberdeen Proving
Ground (APG), MD 21005-5066. The manufacturer shall perform conformance inspection testing
on each production lot and have these test results on file when requested by the contracting
officer. Conformance inspection shall consist of tests for VOC content, condition in container,
total solids, viscosity, color, contrast ratio, fineness of grind, gloss, salt spray resistance, and dry
time as specified in sections 3 and 4. There shall be no failures (see 6.5).
4.4.1 Lot and batch formation. For purposes of conformance inspection, a lot shall consist of all
coatings of the same type, composition and color, from a single uniform batch, produced and
offered for delivery at one time (see 6.3.2). A batch shall consist of all coating material (in U.S.
gallons) manufactured during one continuous operation and forming part of one contract or order
for delivery (see 6.3.2). When required, the manufacturer shall furnish with each lot and/or batch
a certified test report showing that the material has passed the conformance inspection, and that
there has been no formulation or process change from that which resulted in the production of
the qualification inspection sample. The addition of any substance to a batch shall constitute a
new lot.
4.4.2 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with ASTM D3924. Also, unless otherwise stated in the test method or paragraph,
room temperature shall be 73 ± 4 °F (23 ± 2 °C) and a 40 - 70 percent relative humidity.
4.5 Hazardous material. Failure to comply with the hazardous material requirements of FED-
STD-313 shall be cause for rejection.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business