MIL-PRF-24667C
4.3 Conformance inspection. Conformance inspection shall consist of the conformance tests specified in table
XV.
TABLE XV. Conformance tests.
Requirement
Test
Characteristics
Types
paragraph
paragraph
Coefficient of friction 1/ and 3/
All types
Abrasion of arresting cable 1/
Comp L only
Impact resistance 2/
IX
Resistance to wear 1/
IX
Protective cover removal 3/
XI
3.8
4.5.5
3/
Adhesion
XI
3.9
4.5.6
Flash point
IX
4.5.7
Resistance to chemical solutions
(type XI only) 3/
All types
3.11
4.5.8
Appearance of dried coating
IX
4.5.11
Application properties
IX
4.5.12
Color
IX
4.5.13
Size
XI
3.31
4.5.28
Condition in container
IX
4.5.14
Coverage
IX
4.5.15
Drying time
IX
4.5.16
Pot life
IX
4.5.17
Flexibility 1/
III and X
4.5.19
Weight 1/ and 3/
All types
4.5.26
Thickness 3/
XI
3.30
4.5.27
NOTES:
1/
Need only to be performed on first lot and every 19,000 L (5000 gal) thereafter.
2/
Testing on both conditions (4.5.3 (a) and (b)) shall be performed on the first lot delivered and every
19,000 L (5000 gal) thereafter. For all other lots the seawater immersion testing condition (4.5.3 (a))
can be omitted for conformance testing.
3/
Type XI. Testing shall be performed on first lot and every 10,000 square feet of deck covering
thereafter.
4.4 Preparation for testing.
4.4.1 Standard conditions. In case of dispute, with the exception of Type VIII, tests shall be performed at
standard testing conditions, which are 75±5 °F (24±2 °C) and a relative humidity of 50±5 percent, with the exception
of 4.5.12 which shall be performed at the temperatures specified.
4.4.1.1 Type VIII. Low temperature curing materials shall be applied and cured at 35 °F (2 °C). Testing shall
be conducted at standard conditions unless otherwise specified herein.
21
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business