MIL-PRF-24667C
3.35.2 Type XI. Each container shall be clearly labeled with directions for application and with the following
information:
a.
Brand name
b.
Preparation of surface including cleaning agents and primers if required
c.
Method of application
d.
Limit of safe storage and stowage
e.
Safety precautions during application and storage and stowage
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a.
Qualification inspection (see 4.2).
b.
Conformance inspection (see 4.3).
4.2 Qualification inspection. Tests specified in 4.5.23 (pressure cycling), 4.5.24 (strippability), and 4.10
(performance in-service) shall be performed by the Government. Tests at other than a Government laboratory shall
be monitored by the Defense Contract Management Area Operations (DCMAO). Qualification tests shall consist of
the tests specified in table XIII. The service test shall be conducted on an in-service Naval vessel as specified in
4.10 after successful completion of all laboratory tests with the exception of 4.5.25.1, which shall be performed
concurrently. Testing of products on Government ships shall be conducted at the convenience of the Government.